PART NUMBER : D0184-FF3LSGY
Horizontal Cable, CAT 6A, F/FTP, 305m, LSZH Sheath, AWG 23, Grey
• Enhanced Performance meeting Category 6A specifications up to 500 MHz
• Performance compliance to ISO/IEC 11801 and ANSI/TIA-568-C2
• Third Party Delta EC verified
• AWG 23, Solid Bare Annealed Copper
• Low Smoke Zero Halogen
• Fire rated to IEC 60332-1, IEC60332-3C
• 25 Years System Warranty
Datasheet
Availability : In StockDME PROLINK’s Category 6A F/FTP cables are manufactured and tested to the TIA/EIA 568‐C2, EN50173‐1 and ISO/ IEC 11801 Category 6A specifications. DME PROLINK’s Category 6A F/FTP cable is designed for optimal support of High-Speed data protocols delivering 10 Gbps performance to the workstation. Each cable consists of 8 colour coded 23AWG polyolefin Foam-Skin insulated conductors. Each conductors are twisted together to form 4 pairs with varying lengths. Each pairs are then wrapped with Aluminium/ Polyester foil. Then an overall Aluminium/ Polyester foil wrapped around all pairs. DME PROLINK’s CAT6A cable is designed for quick and easy installation where no special tools are required. CAT6A cable is supplied in 305m Drums.
Overall Diameter (mm) | 7.6 ± 0.5mm |
Sheath Surface | Clean, Frap, Satiation |
Insulation Material | Skin Foam Skin PE |
Conductor Diameter (mm) | 0.57 (± 0.005) |
Conductor Material | Solid Bare Annealed Copper |
Mean Input Impedance (Ω) @ 1-250 MHz | 100 ± 5 Ω |
Delay Skew (ns/100m) | Max 45 |
Max. Propagation delay (ns@10MHz): | 518 |
Max. DC Resistance (Ω/Km) @ 20°C | 95.0 |
Capacitance (nF/100m) Max. | 5.6 |
Nominal Velocity of Propagation (NVP) | 74% |
Drain Wire | Yes. TC 0.45mm |
Max. Pulling Force (N) | 100 |
Min. Bend Radius during installation | 8xD (Overall diameter) |
Min. Bend Radius after Installed | 4xD (Overall diameter) |
Storage Temperature Range | ‐20°C to +70°C |
Operating Temperature Range | ‐20°C to +70°C |
Packing Length (Meters) | 305 ± 1.5 |
DME PROLINK’s Category 6A F/FTP cables are manufactured and tested to the TIA/EIA 568‐C2, EN50173‐1 and ISO/ IEC 11801 Category 6A specifications. DME PROLINK’s Category 6A F/FTP cable is designed for optimal support of High-Speed data protocols delivering 10 Gbps performance to the workstation. Each cable consists of 8 colour coded 23AWG polyolefin Foam-Skin insulated conductors. Each conductors are twisted together to form 4 pairs with varying lengths. Each pairs are then wrapped with Aluminium/ Polyester foil. Then an overall Aluminium/ Polyester foil wrapped around all pairs. DME PROLINK’s CAT6A cable is designed for quick and easy installation where no special tools are required. CAT6A cable is supplied in 305m Drums.
Overall Diameter (mm) | 7.6 ± 0.5mm |
Sheath Surface | Clean, Frap, Satiation |
Insulation Material | Skin Foam Skin PE |
Conductor Diameter (mm) | 0.57 (± 0.005) |
Conductor Material | Solid Bare Annealed Copper |
Mean Input Impedance (Ω) @ 1-250 MHz | 100 ± 5 Ω |
Delay Skew (ns/100m) | Max 45 |
Max. Propagation delay (ns@10MHz): | 518 |
Max. DC Resistance (Ω/Km) @ 20°C | 95.0 |
Capacitance (nF/100m) Max. | 5.6 |
Nominal Velocity of Propagation (NVP) | 74% |
Drain Wire | Yes. TC 0.45mm |
Max. Pulling Force (N) | 100 |
Min. Bend Radius during installation | 8xD (Overall diameter) |
Min. Bend Radius after Installed | 4xD (Overall diameter) |
Storage Temperature Range | ‐20°C to +70°C |
Operating Temperature Range | ‐20°C to +70°C |
Packing Length (Meters) | 305 ± 1.5 |
Sorry, no posts matched your criteria.
Electrical Cable Supply Ltd (DME PROLINK),
3135 – 6900 Graybar Road, Richmond,
BC V6W 0A5 Canada
Phone: +1 604 276 9913
Fax: +1 604 276 9915
ECS Global Wire & Cable FZCO (DME PROLINK),
Jebel Ali Free Zone, South Side,
PO Box. 17159, Dubai UAE
Phone: +971 4 811 8000
Fax: +971 4 880 9361