PART NUMBER : D1651-SCAS-F
• Short termination time – no epoxy, no baking.
• Available in SC/APC, SC/UPC, LC/UPC etc.
• Available for “flat” as well as conventional tight- buffered cable.
• Operating Temperature Range: -30°C to +75°C
• Storage Temperature Range: -40°C to +80°C
• Re-usable (Supports multiple terminations)
• 25 Years System Warranty
Datasheet
Availability : 49,000 Pcs In StockDME PROLINK field installable connector is a cost-effective, pre-polished connector, designed for ease of installation and re-use if
so required. It requires no field polishing or epoxy, so no heat-curing devices nor special tooling are needed to facilitate the
termination of the fiber. DME PROLINK quality personals ensures product reliability through rigorous qualification testing to assure cable performance and durability in adverse field environments. Excellent quality control is achieved through intense in-house quality
check and stringent audit acceptance by ISO 9001.
Performance | Conditions | Requirements | Reference |
Insertion Loss | Source Wavelength 1310nm ± 10nm 1490nm ± 10nm 1550nm ± 10nm 1625nm ± 10nm | SC/APC; SC/UPC IL ≤ 0.5 dB | IEC61300-3-4 |
Return Loss | Source Wavelength 1310nm ± 10nm 1490nm ± 10nm 1550nm ± 10nm 1625nm ± 10nm | SC/APC, RL ≥ 50 dB SC/UPC, RL ≥ 60 dB | IEC61300-3-6 |
D1651-SCAS-F
Fiber Optic Field-Installable Connector, SC/APC, Single-mode, Flat Cable
DME PROLINK field installable connector is a cost-effective, pre-polished connector, designed for ease of installation and re-use if
so required. It requires no field polishing or epoxy, so no heat-curing devices nor special tooling are needed to facilitate the
termination of the fiber. DME PROLINK quality personals ensures product reliability through rigorous qualification testing to assure cable performance and durability in adverse field environments. Excellent quality control is achieved through intense in-house quality
check and stringent audit acceptance by ISO 9001.
D1651-SCAS-F
Fiber Optic Field-Installable Connector, SC/APC, Single-mode, Flat Cable
Performance | Conditions | Requirements | Reference |
Insertion Loss | Source Wavelength 1310nm ± 10nm 1490nm ± 10nm 1550nm ± 10nm 1625nm ± 10nm | SC/APC; SC/UPC IL ≤ 0.5 dB | IEC61300-3-4 |
Return Loss | Source Wavelength 1310nm ± 10nm 1490nm ± 10nm 1550nm ± 10nm 1625nm ± 10nm | SC/APC, RL ≥ 50 dB SC/UPC, RL ≥ 60 dB | IEC61300-3-6 |
DME Prolink is the data communication division of ECS global Wire and Cable, that delivers high performance converged datacom solutions. We manufacture complete end-to-end intelligent structured cabling and data center solutions.
Electrical Cable Supply Ltd (DME PROLINK),
3135 – 6900 Graybar Road, Richmond,
BC V6W 0A5 Canada
Phone: +1 604 276 9913
Fax: +1 604 276 9915
ECS Global Wire & Cable FZCO (DME PROLINK),
Jebel Ali Free Zone, South Side,
PO Box. 17159, Dubai UAE
Phone: +971 4 811 8000
Fax: +971 4 880 9361
Introducing DME Prolink Patch Free FDH. Most ideal solution for connecting premises Fiber optic cables with Telco Fiber Access Network through inbuilt GPON Splitters. Approved by Etisalat. IN STOCK. #GPONSolutions #DMEProlink #FTTx