PART NUMBER : D1249-LCA232X1
• Installed in 19” Standard Rack
• Small Size and aesthetic appearance.
• Quick Installation, Reliable Performance and Stable.
• Wide Operating wavelength range
• Good uniformity with respect to PON application
• Cassette Type Splitter – 2:32
• The PLC Splitter comes with pre-connectorised LC/APC connectors. The end faces are still curved but are angled at an industry standard 8°. This maintains a tight connection, and it reduces back reflection to about -70 dB. APC type connector back reflection does not degrade with repeated mating.
• Outer Sheath of Pigtail is PVC
• Fiber Type is G.657A1
• 25 Years System Warranty
• Length of Pigtail is 0.5m
• Diameter for Fiber cable of Pigtail is 2.0mm
• Product Dimension: 430mm (W) x 200mm (D) x 43.5mm (H)
Datasheet
Availability : In StockDME PROLINK’s Splitter panel is a vital component in any GPON/FTTx infrastructure. Designed in conjunction with leading Service Providers This compact, integrated panel offers pre-connectorised presentation of the input and output ports on the front of the panel. Each port is clearly labeled. The splitter consist of waveguides chip, optical fiber array and Pigtails. The Fiber used in DME PROLINK’s splitter panel, is made of pure silica and germanium doped silica. A UV curable acrylate material is applied over the Fiber Cladding as primary protective coating.
DME PROLINK quality personals ensures product reliability through rigorous qualification testing to assure cable performance and durability in adverse field environments. Excellent quality control is achieved through intense in-house quality check and stringent audit acceptance by ISO 9001.
• IEC 60793-1: Optical Fiber Part 1: Generic Specification
• IEC 60793-2: Optical Fiber Part 2: Product Specification
• IEC 60794-2: Optical Fiber Cables Part 2 Indoor cables- Sectional Specification
• ITU-T G652: Characteristics of a Single-mode optical fiber and cable
• ITU-T G.655: Characteristics of a non-zero dispersion-shifted single-mode optical fiber and cable
• ITU-T G.657: Characteristics of a bending-loss insensitive single-mode optical fiber
• YD/T 2000.1-2009: Integrated optical path devices based on planar light wave circuit Part 1: Optical power splitter based on PLC technology
• IEC61300-2-5: Fiber optic interconnecting devices and passive components-Basic test and measurement procedures-Part 2-5:Tests–Torsion
• IEC61300-2-17: Fiber optic interconnecting devices and passive components – Basic test and measurement procedures–Part 2-17: Tests –Cold
• IEC61300-2-22: Fiber optic interconnecting devices and passive components-Basic test and measurement procedures-Part 2-22: Tests–Change of temperature
• IEC61300-3-1: Fiber optic interconnecting devices and passive components-Basic test and measurement procedures–Visual examination
• IEC61300-3-6: Fiber optic interconnecting devices and passive components –Basic test and measurement procedures-Examinations and measurements -Return loss
• IEC61300-3-34: Fiber optic interconnecting devices and passive components –Basic test and measurement procedures-Examinations and measurements–Attenuation of random mated connectors.
• IEC 61754-20: Fiber Optic interconnecting devices and passive components – Fiber Optic
Connector Interfaces – Part 20: Type LC connector family
• IEC 61300-3-1: Fiber Optic interconnecting devices and passive components – Basic Test and Measurement procedures – Visual Examination
• IEC 61300-2-5: Fiber optic interconnecting devices and passive components – Basic test and measurement procedures- Tests –Torsion
• IEC 61300-2-17: Fiber optic interconnecting devices and passive components – Basic test and measurement procedures –Tests –Cold
• IEC 61300-2-22: Fiber Optic interconnecting devices and passive components – Basic Test and Measurement procedures – Examinations and Measurements – Change of Temperature.
• IEC 61300-3-6: Basic Test and Measurement procedures – Examinations and Measurements – Return loss
• IEC 61300-3-34: Basic Test and Measurement procedures – Examinations and Measurements – Attenuation of random mated connectors
• YDT 2000.1-2009 Integrated optical path devices based on planar lightwave circuit Part 1: Optical power splitter based on PLC technology
Splitter Type | 2×32 |
Channel wavelength (nm) | 1260-1650 |
Insertion Loss (dB) | ≤ 17.9 |
Loss Uniformity (dB) | ≤ 1.5 |
Return Loss (dB) | ≥ 50 (APC) |
Polarization Dependent Loss (dB) | ≤ 0.3 |
Directivity (dB) | ≥ 55 |
Operating Temperature Range | ‐40°C to +85°C |
Storage Temperature Range | ‐40°C to +85°C |
Fiber Type | Single mode OS2 |
Connector Type | LC |
Connector Surface | APC (Angled Physical Contact) |
Insertion Loss (dB) | ≤ 0.3 |
Return Loss (dB) | ≥ 60 |
Operating Temperature Range | ‐25°C to +70°C |
Storage Temperature Range | ‐25°C to +70°C |
Durability | > 500 times |
Standard | IEC 601754-20 |
Fiber Type | Single mode |
Adapter Type | LC |
Insertion Loss (dB) | ≤ 0.20 |
Repeatability (dB) | ≤ 0.20 |
Interchangeability (dB) | ≤ 0.20 |
Operating Temperature Range | ‐25°C to +70°C |
Storage Temperature Range | ‐25°C to +70°C |
Durability | > 500 times |
Standard | IEC 601754-20 |
Tests | Test Content and Criteria Data |
Visual Examination | Be smooth, clean, without oily be soiled, no scar and crack. The whole device is firm, the tail fiber without loosening or with the connector plug is smooth. |
Insertion Loss | ≤ 0.3dB (Connector) |
Return Loss | ≥ 60dB (Connector) |
Mechanical Durability | Plug and pull out for 500 times, No scratch and meet optical performance |
Cold | Temperature:-40°C,-20°C, -10°C.(Choose one according to requirements). Time: 96h. The rate of change of temperature shall not exceed 1 °C/min, averaged over a maximum period of 5 min. Result: no scar and crack. |
Torsion | Load: 2N. Twist angle: 180°. Number of cycles: 25 |
Temperature Cycling | Range:-10°C~+60°C, 5 cycle. Change speed:(1±0.2)°C/min; Result: ΔIL ≤ 0.2dB, ΔRL<5dB |
D1249-LCA232X1
Fiber Optic Splitter Panel, 19″ Rack-mount, LC/APC, 2:32 Splitter, 1 Instance
DME PROLINK’s Splitter panel is a vital component in any GPON/FTTx infrastructure. Designed in conjunction with leading Service Providers This compact, integrated panel offers pre-connectorised presentation of the input and output ports on the front of the panel. Each port is clearly labeled. The splitter consist of waveguides chip, optical fiber array and Pigtails. The Fiber used in DME PROLINK’s splitter panel, is made of pure silica and germanium doped silica. A UV curable acrylate material is applied over the Fiber Cladding as primary protective coating.
DME PROLINK quality personals ensures product reliability through rigorous qualification testing to assure cable performance and durability in adverse field environments. Excellent quality control is achieved through intense in-house quality check and stringent audit acceptance by ISO 9001.
• IEC 60793-1: Optical Fiber Part 1: Generic Specification
• IEC 60793-2: Optical Fiber Part 2: Product Specification
• IEC 60794-2: Optical Fiber Cables Part 2 Indoor cables- Sectional Specification
• ITU-T G652: Characteristics of a Single-mode optical fiber and cable
• ITU-T G.655: Characteristics of a non-zero dispersion-shifted single-mode optical fiber and cable
• ITU-T G.657: Characteristics of a bending-loss insensitive single-mode optical fiber
• YD/T 2000.1-2009: Integrated optical path devices based on planar light wave circuit Part 1: Optical power splitter based on PLC technology
• IEC61300-2-5: Fiber optic interconnecting devices and passive components-Basic test and measurement procedures-Part 2-5:Tests–Torsion
• IEC61300-2-17: Fiber optic interconnecting devices and passive components – Basic test and measurement procedures–Part 2-17: Tests –Cold
• IEC61300-2-22: Fiber optic interconnecting devices and passive components-Basic test and measurement procedures-Part 2-22: Tests–Change of temperature
• IEC61300-3-1: Fiber optic interconnecting devices and passive components-Basic test and measurement procedures–Visual examination
• IEC61300-3-6: Fiber optic interconnecting devices and passive components –Basic test and measurement procedures-Examinations and measurements -Return loss
• IEC61300-3-34: Fiber optic interconnecting devices and passive components –Basic test and measurement procedures-Examinations and measurements–Attenuation of random mated connectors.
D1249-LCA232X1
Fiber Optic Splitter Panel, 19″ Rack-mount, LC/APC, 2:32 Splitter, 1 Instance
Splitter Type | 2×32 |
Channel wavelength (nm) | 1260-1650 |
Insertion Loss (dB) | ≤ 17.9 |
Loss Uniformity (dB) | ≤ 1.5 |
Return Loss (dB) | ≥ 50 (APC) |
Polarization Dependent Loss (dB) | ≤ 0.3 |
Directivity (dB) | ≥ 55 |
Operating Temperature Range | ‐40°C to +85°C |
Storage Temperature Range | ‐40°C to +85°C |
Fiber Type | Single mode OS2 |
Connector Type | LC |
Connector Surface | APC (Angled Physical Contact) |
Insertion Loss (dB) | ≤ 0.3 |
Return Loss (dB) | ≥ 60 |
Operating Temperature Range | ‐25°C to +70°C |
Storage Temperature Range | ‐25°C to +70°C |
Durability | > 500 times |
Standard | IEC 601754-20 |
Fiber Type | Single mode |
Adapter Type | LC |
Insertion Loss (dB) | ≤ 0.20 |
Repeatability (dB) | ≤ 0.20 |
Interchangeability (dB) | ≤ 0.20 |
Operating Temperature Range | ‐25°C to +70°C |
Storage Temperature Range | ‐25°C to +70°C |
Durability | > 500 times |
Standard | IEC 601754-20 |
• IEC 61754-20: Fiber Optic interconnecting devices and passive components – Fiber Optic
Connector Interfaces – Part 20: Type LC connector family
• IEC 61300-3-1: Fiber Optic interconnecting devices and passive components – Basic Test and Measurement procedures – Visual Examination
• IEC 61300-2-5: Fiber optic interconnecting devices and passive components – Basic test and measurement procedures- Tests –Torsion
• IEC 61300-2-17: Fiber optic interconnecting devices and passive components – Basic test and measurement procedures –Tests –Cold
• IEC 61300-2-22: Fiber Optic interconnecting devices and passive components – Basic Test and Measurement procedures – Examinations and Measurements – Change of Temperature.
• IEC 61300-3-6: Basic Test and Measurement procedures – Examinations and Measurements – Return loss
• IEC 61300-3-34: Basic Test and Measurement procedures – Examinations and Measurements – Attenuation of random mated connectors
• YDT 2000.1-2009 Integrated optical path devices based on planar lightwave circuit Part 1: Optical power splitter based on PLC technology
Tests | Test Content and Criteria Data |
Visual Examination | Be smooth, clean, without oily be soiled, no scar and crack. The whole device is firm, the tail fiber without loosening or with the connector plug is smooth. |
Insertion Loss | ≤ 0.3dB (Connector) |
Return Loss | ≥ 60dB (Connector) |
Mechanical Durability | Plug and pull out for 500 times, No scratch and meet optical performance |
Cold | Temperature:-40°C,-20°C, -10°C.(Choose one according to requirements). Time: 96h. The rate of change of temperature shall not exceed 1 °C/min, averaged over a maximum period of 5 min. Result: no scar and crack. |
Torsion | Load: 2N. Twist angle: 180°. Number of cycles: 25 |
Temperature Cycling | Range:-10°C~+60°C, 5 cycle. Change speed:(1±0.2)°C/min; Result: ΔIL ≤ 0.2dB, ΔRL<5dB |
DME Prolink is the data communication division of ECS global Wire and Cable, that delivers high performance converged datacom solutions. We manufacture complete end-to-end intelligent structured cabling and data center solutions.
Introducing DME Prolink Patch Free FDH. Most ideal solution for connecting premises Fiber optic cables with Telco Fiber Access Network through inbuilt GPON Splitters. Approved by Etisalat. IN STOCK. #GPONSolutions #DMEProlink #FTTx
Electrical Cable Supply Ltd (DME PROLINK),
3135 – 6900 Graybar Road, Richmond,
BC V6W 0A5 Canada
Phone: +1 604 276 9913
Fax: +1 604 276 9915
ECS Global Wire & Cable FZCO (DME PROLINK),
Jebel Ali Free Zone, South Side,
PO Box. 17159, Dubai UAE
Phone: +971 4 811 8000
Fax: +971 4 880 9361